FAQ - Line Shaft, flexible Shaft Coupling and Torque Limiter
Bellows Couplings
Q) What
causes bellows couplings to fail?
A) The most common failure
in bellows couplings is caused by parallel shaft misalignment
in excess of the coupling’s maximum tolerance. While
bellows couplings offer a very low restoring force on shaft
bearings when compared to other flex couplings, their own
tolerance for shaft offset normally does not exceed 0.010
inch. A small line shaft with double bellows however can
be a much more flexible coupling, increasing offset tolerance
often by over 10 times.
Back to the FAQ about flexible
Shaft Couplings, Torque Limiters and Line Shafts